108 MW 2014 MAN 18V32/40CD Complete Power Plant

Specifications
| Manufacturer | MAN |
| Model | 18V32/40CD |
| Year | 2014 |
| Condition | Used |
| Stock Number | 00063 |
| Fuel Type | HFO |
| Megawatts | 108 |
| Year of built | 2014 |
| * Manufacturer | MAN |
| * Model | 18V32/40 |
| Engine output | 8.75 MW each |
| * Type | Medium-speed diesel engine |
| * Average running hours | ~9,106 hours |
| * Voltage | 11 kV |
| * Frequency | 50 Hz |
Description
The 2014 MAN 18V32/40CD power plant is a heavy fuel oil facility offering a total capacity of 108 MW through 12 identical generating units. Each unit is capable of producing 8.75 MW and is paired with Hyundai Heavy Industries 10,324 kVA alternators. The system operates at 11 kV and 50 Hz, and each unit has logged approximately 9,100 running hours. This used power plant is designed for continuous base-load operation and includes a full complement of ancillary equipment, such as transformers, switchgear, and control systems. This MAN power plant is ideal for various applications, including independent power producer (IPP) projects, utility power generation, and industrial captive power solutions. It can also serve as a primary or backup power source for data centers. Its medium-speed engine technology is known for efficiency, longevity, and easy access to spare parts globally, making it a reliable and scalable option for on-site power generation needs.
Engine
- Manufacturer: MAN
- Model: 18V32/40CD
- Type: Medium-speed diesel engine
- Number of cylinders: 18 (V-configuration)
- Fuel: Diesel (HFO-capable depending on configuration)
- Year of manufacture: 2014
- Rated mechanical output: 8,750 kW
- Average running hours: ~9,106 hours
Alternator
- Manufacturer: Hyundai Heavy Industries
- Rated apparent power: 10,324 kVA
- Rated active power: ≈ 8.75 MW @ PF 0.85
- Voltage: 11 kV
- Frequency: 50 Hz
- Phase: 3-phase
- Cooling: Air / hydrogen (as per Hyundai standard design)
Electrical Characteristics
- Power factor: 0.85
- Net electrical output: ~8.75 MW
- Grid compatibility: Medium-voltage grid connection (11 kV)